How To Wire A 20 Amp Double Pole Breaker

The perfect wire gauge of a 20 amp breaker is the #12 AWG wire. This is a bigger wire with 25A ampacity and can handle 20 amp current while also satisfying the NEC 80% rule for safety.

What wires go where on a double pole breaker?

1) Connect the ground wire to the ground bus of the subpanel. 2) Connect the neutral wire to the neutral bus. 3) Snap the breaker to a hot bus. 4) Insert the hot wire into the breaker lug and tighten it down.

How do you wire a two pole circuit breaker?

Steps on How to Wire a Double Pole Circuit Breaker

  1. Switch off the main breaker & test for current.
  2. Examine the panel's wiring. ...
  3. Wire strip the circuit wires. ...
  4. Connect your double pole circuit breaker. ...
  5. Reassemble the breaker panel.

What is a double pole 20 amp breaker used for?

The breakers themselves are relatively narrow and occupy a single slot in the home's breaker box. Double-pole breakers, on the other hand, are typically rated for 20 to 60 amps and supply 240-volt power to large appliances, like electric dryers and ranges.

How far can you run 12 2 wire on a 20 amp breaker?

You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

Can you put 14 gauge wire on a 20 amp breaker?

You cannot use any 14 gauge wire on a 20 amp circuit. This is true, even running to a light fixture that has smaller wires built in. The wires built into the fixture are allowed as part of a manufactured assembly. However, any added wire must be appropriate to the circuit breaker protecting the wire.

Does a 2 pole breaker need a neutral?

A double pole breaker is used for an installation without a neutral wire. In the case of the American 240 volts, the electricity is provided with two legs of 120 volts. Each leg needs its own breaker in a double-pole arrangement. You don't want a single breaker to trip because you will still get 120 Volts on the line.

Can I use just one side of a double pole breaker?

A double pole switch can be used to control light and a fan or 2 lights on separate circuits. It is easy to wire a double pole switch to work as a single pole switch because only one side is used instead of both. Single pole switch is referred as a single pole, single throw switch.

Is a double pole breaker twice the amps?

Since each leg of 240 volt circuit offers 120 volt potential to ground, then you're getting two legs of out-of-phase 120 volt when you use double breaker, and doing so doubles the voltage and doubles the watts (power), it does not halve the amps.

How many amps can a 2 pole 20 amp breaker handle?

(A 30A branch circuit is unusual. Typically, anything over 20A is for a certain purpose: a clothes dryer outlet, range outlet, etc.) No, a two pole 20 amp breaker is for loads that require 220 volts. If one hot is over 20 amps the two pole breaker will trip since the breaker handles are attached together by a pin.

Why would you use a double pole breaker?

Double-pole breakers have two hot wires that are connected by a single neutral wire. That means if there's a short circuit on either of the poles' hot wires, both trip. These breakers can be used to serve two separate 120-volt circuits or they can serve a single 240-volt circuit, such as your central AC's circuit.

What size wire do I need for 20 amp 240 volt?

A 20-amp 240-volt circuit calls for 12-gauge wire; a 30-amp circuit calls for 10-gauge wire; a 40-amp circuit calls for 8-gauge wire; and a 50-amp circuit calls for 6-gauge wire.

Can I use 8 gauge wire on a 20 amp circuit?

Looking up the brand of breaker that's in my panel, #8 wire fits the 20 amp breaker just fine (it is the largest size that breaker is listed for, but no adapter needed.)

Can you use 10 gauge wire on a 20 amp breaker?

Yes, you can use 10 AWG copper conductors with a 20 ampere breaker. The smallest size conductors you could use with a 20 ampere breaker, are 12 AWG copper conductors. There's no problem using larger conductors, other than cost to you, and difficulties associated with working with thicker conductors.

How many amps will a 12 2 wire carry?

You can use a 20 amp circuit breaker with 12/2 Romex as 12/2 wire is rated for 20 amps.

What happens if you use 14 2 wire on a 20 amp circuit?

If the outlets are on a 20-amp circuit, 14/2 wire is not sufficient. You will have to step up to 12/2 wire for all outlets on 20-amp circuits. Using 14-gauge wire (such as 14/2) to wire outlets on a 20-amp circuit can result in overheating and a dangerous electrical fire.

Can you have 15 amp outlets on a 20 amp breaker?

Can You Put A 15 Amp Outlet On A 20 Amp Circuit? Yes. You can very well put a 15 amp receptible on a 20 amp circuit. In fact, with the highest allowable amps on a 20 amp circuit in mind, you can put a 16 amp outlet on a 20 amp circuit.

Can you use 12 gauge wire on a 20 amp breaker?

“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”

Why do some double pole breakers only have one switch?

A two pole breaker that has only one switch is called an internal trip breaker. The two phases disconnects are tied together inside the breaker itself so that if one phase trips it kills power to both. Because the two phases are tripped inside the breaker, it's considered an internal trip.

Is neutral the same as ground?

While a ground wire and neutral wire are connected, they serve different functions in the overall electrical scheme. The neutral wire is part of the normal flow of current, while the ground wire is a safety measure in case the hot wire comes in contact with the metal casing of an appliance or other shock hazard.